Presents analysis methods for rectangular tanks
containing fluids. Describes the analysis procedure and gives tables of
coefficients for moments, shears, and deflections due to uniform and triangular
loads. Support conditions considered are free and hinged tops as well as hinged
and fixed bases. Also covered is durability, minimum reinforcement, crack
control, formwork considerations, and multi-cell tanks. Comprehensive design
examples illustrate the use of the tables and design aids.